Data retention period during power outage
≥ 10 years
Communication module
PLC, RF, GPRS
Frequency
50Hz
Rated (maximum) current
10 (60)А
Maximum operating voltage
0.7 Un ÷ 1.2 Un
Normal operating voltage
0.8 Un ÷ 1.1 Un
Rated voltage
220V
Accuracy class
1.0
Single-phase electronic electricity meter
EX18
Description
Technical Specifications
Construction
Wiring diagram
Test type and connection
Regulatory Compliance
Communication protocol: optocoupler: IEC 62056-21, Mode E; RS485 port: DLMS; GPRS: DLMS TCP/IP; PLC/RF: DLMS.
Connection port: IR port: 1200bps~9600bps; connection port RS485: 9600bps; connection port GPRS or PLC.
Main tests: in accordance with the standard IEC62052-11.
Certified and listed in the State Register of Measuring Instruments of the Republic of Uzbekistan
IEC62056-21, IEC62056-61, IEC62056-53, IEC62056-46, IEC62056-42
IEC 62053-21, IEC 62053-23
IEC 62052-11
Description
Technical Specifications
Construction
Wiring diagram
Meter Type
3P4W CTVT
Active power accuracy class
1.0
Reactive power accuracy class
2.0
Current
1 (2)A / 5 (6)A
Power consumption
Line current: <0.5 VA;
Line voltage: <2.0 W;
Power consumption: <10 VA
Pulse amplitude
1000imp/kWh,
1000imp/kvarh
Starting current
Active 0.001 In,
Reactive 0.002 In
Operating temperature range
-40℃ ~ +70℃
Humidity range
5% ~ 95%RH
Storage temperature range
-40℃ ~ +80℃
Data retention period during power outage
≥ 10 years
Communication module
PLC, RF, GPRS
Frequency
50Hz
Rated (maximum) current
10 (60)А
Maximum operating voltage
0.7 Un ÷ 1.2 Un
Normal operating voltage
0.8 Un ÷ 1.1 Un
Rated voltage
220V
Accuracy class
1.0
Single-phase electronic electricity meter
EX18
Description
Technical Specifications
Construction
Wiring Diagram
Dimensions
220 X 125X 75.5mm
Weight
1kg
Material of the meter housing
Polycarbonate
Impact Vibration
IEC62052-11 (5.2.2.1, 5.2.2.2 & 5.2.2.3)
Seal
Seals on the PLC module cover – 2 pcs.
Seals on the top cover – 2 pcs.
Seal on the top cover button – 1 pc.
Seal on the terminal cover – 1 pc.
Data retention period during power outage
≥ 10 years
Communication module
PLC, RF, GPRS
Frequency
50Hz
Rated (maximum) current
10 (60)А
Maximum operating voltage
0.7 Un ÷ 1.2 Un
Normal operating voltage
0.8 Un ÷ 1.1 Un
Rated voltage
220V
Accuracy class
1.0
Single-phase electronic electricity meter
EX18
We will find a solution for your task
Submit your request and our specialists will contact you shortly to answer any questions you may have
By clicking on the button, you agree to the terms and conditions for the processing of personal data and the Privacy Policy
Phone
E-mail
Website development
Elektron Xisoblagich 2026 © All rights reserved
Tashkent, Yashnabad District, Tashselmash Residential Area, 4k2
Elektron Xisoblagich
Elektron Xisoblagich
Elektron Xisoblagich
Elektron Xisoblagich
Elektron Xisoblagich
Submit a request
Fill out the form and our specialists will contact you shortly
By clicking the button, you agree to the terms and conditions for the processing of personal data and the Privacy Policy
Made on
Tilda